Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 29, 2016, 11:46 PM
  • H 0670_H 0669_20160712_043332.mp4

Date
06/29/2016
W/O
574527
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00941
PipeID
P11077
Time
4:46 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3611
Sewer Name
H JOINT OUTFALL H - UNIT 9B
City
PICO RIVERA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
03
Purpose
Routine Assessment
Project
WO_574527_TV18074_JULY2016
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
25 in.
Width
25 in.
Upstream MH
H 0670
Downstream MH
H 0669
Dir. of Survey
Downstream
Length Surveyed
522 ft.
Total Length
522.1 ft.
Structural Index
2
Structural Quick
2T00
Structural Rating
208
O&M Index
2
O&M Quick
2]00
O&M Rating
302
Overall Index
2
Overall Quick
Overall Rating
510
Pipe schematic from manhole H 0670 to H 0669
MH: H 0670MH: H 0669downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 06700 ft. MWL - Water Level, 15 %of cross sectional area0 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start0 ft. MWM - Water Mark, 20 %of cross sectional area285.1 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - OTHER387 ft. MGO - General Observation - RUN LIST STATES MH AT 387'520.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish520.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish520.1 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish - OTHER522.1 ft. AMH - Downstream Manhole, Survey Ends - H 0669

Observation photos (3)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    0 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    0 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Settled Other,  10 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start - OTHER

    285.1 ft. - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - OTHER

Observations (11)

DistanceCodeObservation
0AMHH 0670
520.1SSS
0MWL
520.1DAGS
0SSS
520.1DSZOTHER
522.1AMHH 0669
0DAGS
0MWM
285.1DSZOTHER
387MGORUN LIST STATES MH AT 387'

Properties (4)

additional_info
SC305790
custom_field_two
3
customer
LACSD
datetime
2016-06-29T16:46:41-07:00