Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 17, 2018, 07:52 AM
  • 15 0928_15 0927_4172018_021013.mp4

Date
04/17/2018
W/O
0700722
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00609
PipeID
P12711
Time
12:52 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0824
Sewer Name
15 HILL DRIVE EXTENSION RELIEF TRUNK
City
MONTEREY PARK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
26
Purpose
Routine Assessment
Project
20180417MDM_HILL_DRIVE_EXTENSION_RELIEF_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Upstream MH
15 0928
Downstream MH
15 0927
Dir. of Survey
Downstream
Length Surveyed
302.9 ft.
Total Length
302.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 0928 to 15 0927
MH: 15 0928MH: 15 0927downstream0 ft. AMH - Upstream Manhole, Survey Begins - 2"05AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area8 ft. MGO - General Observation - 8' VCP155.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active177.9 ft. MWM - Water Mark, 40 %of cross sectional area224.9 ft. MWM - Water Mark, 30 %of cross sectional area285.9 ft. MGP - General Photograph302.9 ft. AMH - Downstream Manhole, Survey Ends - 2:25AM

Observation photos (2)

  • General Observation - 8' VCP

    8 ft. - General Observation - 8' VCP

  • General Photograph

    285.9 ft. - General Photograph

Observations (9)

DistanceCodeObservation
155.9TFActive
0AMH2"05AM
0MWL
302.9AMH2:25AM
224.9MWM
177.9MWM
285.9MGP
0MWM
8MGO8' VCP

Properties (3)

custom_field_two
4
customer
LACSD
datetime
2018-04-17T00:52:42-07:00