Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 21, 2016, 03:34 PM
  • 08 0644_08 0476_20160121_074221.mp4

Date
01/21/2016
W/O
531045
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00025
PipeID
P20116
Time
7:34 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3163
Sewer Name
08 216TH STREET RELOCATION TRUNK
City
CARSON
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_531045_TV08101_OCT2015
Sewer Type
GRAVITY
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Upstream MH
08 0644
Downstream MH
08 0476
Dir. of Survey
Downstream
Length Surveyed
32.5 ft.
Total Length
32.5 ft.
Structural Index
5
Structural Quick
5200
Structural Rating
10
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
5
Overall Quick
Overall Rating
14
Pipe schematic from manhole 08 0644 to 08 0476
MH: 08 0644MH: 08 0476downstream0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 06440 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. MGO - General Observation - MAGNEZIUM H.O COATING 50%2 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start13.1 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO, Start32.5 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO, Finish32.5 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish32.5 ft. AMH - Downstream Manhole, Survey Ends - 08 047632.5 ft. MGO - General Observation - MAGNEZIUM H.O COATING 50% FINISH

Observation photos (2)

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO, Start

    13.1 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO, Start

Observations (10)

DistanceCodeObservation
0MWL
32.5SRC
32.5SRV
13.1SRC
32.5AMH08 0476
32.5MGOMAGNEZIUM H.O COATING 50% FINISH
2MGOMAGNEZIUM H.O COATING 50%
2SRV
0AMH08 0644
0MWM

Properties (4)

additional_info
SC224975
custom_field_two
2
customer
LACSD
datetime
2016-01-21T07:34:48-08:00