Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 6, 2018, 03:34 PM
  • A 0437_A 0436_462018_091025.mp4

Date
04/06/2018
W/O
0696832
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00323
PipeID
P08159
Time
8:34 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7677
Sewer Name
A JOA-1A LOS COYOTES WRP INTERCEPTOR
City
SOUTH GATE
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
26
Purpose
Routine Assessment
Project
20180406SHO_JOA_1A_LOS_COYOTES_WRP_INTERCEPTOR
Material
Reinforced Concrete Pipe
Shape
Circular
Height
60 in.
Upstream MH
A 0437
Downstream MH
A 0436
Dir. of Survey
Downstream
Length Surveyed
730.5 ft.
Total Length
730.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole A 0437 to A 0436
MH: A 0437MH: A 0436downstream0 ft. AMH - Upstream Manhole, Survey Begins - 09100 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area8 ft. MGO - General Observation - 90% MAG COAT INTACT278.6 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE606.5 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE730.5 ft. AMH - Downstream Manhole, Survey Ends - 1010

Observation photos (1)

  • General Observation - 90% MAG COAT INTACT

    8 ft. - General Observation - 90% MAG COAT INTACT

Observations (7)

DistanceCodeObservation
278.6TFAACTIVE
8MGO90% MAG COAT INTACT
730.5AMH1010
0AMH0910
0MWM
606.5TFAACTIVE
0MWL

Properties (4)

custom_field_three
90% MAG COAT INTACT
custom_field_two
4
customer
LACSD
datetime