Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 30, 2018, 05:58 AM
Date
03/29/2018
W/O
698202
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00093
PipeID
P08960
Time
10:58 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5504
Sewer Name
B JOINT OUTFALL B - UNIT 5C
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
11
Purpose
Routine Assessment
Project
WO_698202_DISTRICT16_APR2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
B 0448
Downstream MH
B 0447
Dir. of Survey
Downstream
Length Surveyed
302.6 ft.
Total Length
302.6 ft.
Structural Index
3
Structural Quick
3K00
Structural Rating
180
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
184
Pipe schematic from manhole B 0448 to B 0447
MH: B 0448MH: B 0447downstream0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. MGO - General Observation - MAG COATING THROUGHOUT 60%0 ft. AMH - Upstream Manhole, Survey Begins - B 04480 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start14 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 4"75.5 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 4"136.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 4"198.3 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 4"256.1 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 4"302.6 ft. MGO - General Observation - CAPPED CONNECTIONS AT MH 3 AND 9 O'CLOCK302.6 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish302.6 ft. AMH - Downstream Manhole, Survey Ends - B 0447

Observation photos (1)

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
0MWL
0MGOMAG COATING THROUGHOUT 60%
256.1TFA
302.6MGOCAPPED CONNECTIONS AT MH 3 AND 9 O'CLOCK
0AMHB 0448
0MWM
2SAV
302.6SAV
136.7TFC
75.5TFA
302.6AMHB 0447
14TFA
198.3TFA

Properties (4)

additional_info
SC358513
custom_field_two
2
customer
LACSD
datetime
2018-03-29T22:58:34-07:00