Section#1_08 0010_08 0009__3312018__G6984.mp4
2 ft. - General Observation - 90% MISSING TILES 10:00 TO 2:00
2.2 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES
2.2 ft. - General Observation - MAG COAT 90% START
10.8 ft. - Surface Aggregate Missing, from 11 to 01 o'clock, within 8 inches of joint: NO - SEVERE AGG
26.6 ft. - General Observation - 2 ROWS TILES IN PLACE
30.1 ft. - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
39.4 ft. - General Observation - MISSING TILES 5% START
52.4 ft. - General Observation - MISSING TILES 100% 5 ROWS
96.1 ft. - General Observation - MAG COAT 60% START
211.6 ft. - Water Mark, 80 %of cross sectional area
211.6 ft. - General Observation - NEW MISSING TILES
244.6 ft. - Surface Aggregate Missing, from 10 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG AREAS OF MISSING TILES
306.4 ft. - General Observation - 33" RCP-CTL
337.4 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR
337.4 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
| Distance | Code | Observation |
|---|---|---|
| 143.3 | MGO | 2 ROWS MISSING TILES |
| 52.4 | MGO | MISSING TILES 100% 5 ROWS |
| 306.4 | MGO | 33" RCP-CTL |
| 341.3 | MGO | MISSING TILES 5% FINISH |
| 341.6 | AMH | 1:40AM |
| 0 | AMH | 12:20AM |
| 337.4 | SRV | LONG REBAR |
| 244.6 | SAM | SEVERE AGG AREAS OF MISSING TILES |
| 0 | MWL | — |
| 2 | MGO | 90% MISSING TILES 10:00 TO 2:00 |
| 312.5 | MWM | — |
| 30.1 | SRV | CIRCUM REBAR |
| 312.5 | MWL | — |
| 211.6 | MWM | — |
| 26.6 | MGO | 2 ROWS TILES IN PLACE |
| 2.2 | SAM | SEVERE AGG AREAS OF MISSING TILES |
| 341.3 | SAM | AREAS OF MISSING TILES |
| 0 | MWM | — |
| 10.8 | SAM | SEVERE AGG |
| 211.6 | MGO | NEW MISSING TILES |
| 2.2 | MGO | MAG COAT 90% START |
| 341.3 | MGO | 60% MAG COAT FINISH |
| 96.1 | MGO | MAG COAT 60% START |
| 39.4 | MGO | MISSING TILES 5% START |
| 337.4 | SRV | CIRCUM REBAR |