Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 28, 2018, 06:14 PM
  • Section#10_A 1045_A 0340__3282018__G6982.mp4

Date
03/28/2018
W/O
0686845
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00325
PipeID
P21168
Time
11:14 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6982
Sewer Name
A JOA-1A SAN JOSE CREEK WRP INTERCEPTOR
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
16
Purpose
Routine Assessment
Project
20180327DF_JOA_1ASAN_JOSE_CREEK_WRP_INTERCEPTOR
Material
Reinforced Concrete Pipe
Shape
Circular
Height
63 in.
Upstream MH
A 1045
Downstream MH
A 0340
Dir. of Survey
Downstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
5
O&M Quick
5141
O&M Rating
9
Overall Index
4
Overall Quick
Overall Rating
14
Pipe schematic from manhole A 1045 to A 0340
MH: A 1045MH: A 0340downstream0 ft. MWL - Water Level, 100 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 11:34 AM0 ft. MWM - Water Mark, 100 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES2 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES - 50% MAG2 ft. LD - Alignment Down, 45 %2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES2.1 ft. MGO - General Observation - AIRLINE2.1 ft. MSA - Survey Abandoned - 11:40 AM

Observation photos (7)

  • Water Level, 100 %of cross sectional area

    0 ft. - Water Level, 100 %of cross sectional area

  • Water Mark, 100 %of cross sectional area

    0 ft. - Water Mark, 100 %of cross sectional area

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES - 50% MAG

    2 ft. - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES - 50% MAG

  • Alignment Down, 45 %

    2 ft. - Alignment Down, 45 %

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

  • General Observation - AIRLINE

    2.1 ft. - General Observation - AIRLINE

Observations (9)

DistanceCodeObservation
0MWL
0AMH11:34 AM
2SAV
2SZ50% MAG
2LD
2.1MGOAIRLINE
2SSS
2.1MSA11:40 AM
0MWM

Properties (4)

additional_info
VIEW OF DOWNLEG FROM THE U/S SIPHON. CORRECT TAPE NUMBER IS (G6982)
custom_field_two
5
customer
LACSD
datetime
2018-03-28T11:14:56-07:00