- Date
- 03/21/2018
- W/O
- PENDING
- Weather
- Dry
- Operator/Surveyor
- SANTIAGO OBREGON
- Sewer ID
- Z00027
- PipeID
- P07607
- Time
- 11:02 AM
- Certificate
- U-1014-06022541
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0785
- Sewer Name
- E JOINT OUTFALL E - UNIT 1
- City
- COMPTON
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 20
- Purpose
- Routine Assessment
- Project
- 20180321SHO_JOINT_OUTFALL_E_UNIT_1
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 42 in.
- Upstream MH
- E 0020
- Downstream MH
- G 0094
- Dir. of Survey
- Upstream
- Length Surveyed
- 47.9 ft.
- Total Length
- 47.9 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 2
Pipe schematic from manhole E 0020 to G 0094 Observation photos (3)

9.2 ft. - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO, Start - UNKNOWN DEBRIS

9.2 ft. - General Observation - 90% MAG COAT INTACT

47.9 ft. - Survey Abandoned - DEBRIS