Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 19, 2018, 07:53 AM
  • 15 0665_15 0664_3192018_010727.mp4

Date
03/19/2018
W/O
0695512
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00602
PipeID
P12557
Time
12:53 AM
Certificate
U-1014-0622543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0777
Sewer Name
15 EL MONTE AVENUE TRUNK
City
TEMPLE CITY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
11
Purpose
Maintenance Related
Project
20180319MDM_EL_MONTE_AVENUE_TRUNK
Material
NRCP
Shape
Circular
Height
12 in.
Upstream MH
15 0665
Downstream MH
15 0664
Dir. of Survey
Downstream
Length Surveyed
266.6 ft.
Total Length
266.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole 15 0665 to 15 0664
MH: 15 0665MH: 15 0664downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 12:55AM10.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open34.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped70.6 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 5" - Open116.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped149.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open155.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open188.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped236.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped261.2 ft. MWL - Water Level, 40 %of cross sectional area266 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped266.2 ft. MGO - General Observation - LINK PIPE266.2 ft. DSZ - Deposits Settled Other, 30 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO - DEBRIE AT LINK PIPE266.6 ft. MSA - Survey Abandoned - 30% BLOCKAGE(1:20AM)

Observation photos (2)

  • General Observation - LINK  PIPE

    266.2 ft. - General Observation - LINK PIPE

  • Deposits Settled Other,  30 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: NO -  DEBRIE AT LINK PIPE

    266.2 ft. - Deposits Settled Other, 30 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO - DEBRIE AT LINK PIPE

Observations (16)

DistanceCodeObservation
261.2MWL
10.2TFOpen
70.6TFOpen
0MWM
188.4TFCCapped
236.3TFCCapped
155.1TFOpen
0MWL
0AMH12:55AM
34.7TFCCapped
116.4TFCCapped
266.6MSA30% BLOCKAGE(1:20AM)
266.2MGOLINK PIPE
266TFCCapped
266.2DSZDEBRIE AT LINK PIPE
149.7TFOpen

Properties (3)

additional_info
LINK PIPE INSPECTION
customer
LACSD
datetime
2018-03-19T00:53:38-07:00