Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 26, 2018, 10:59 AM
  • 21 1089_21 1088 _26022018_030602.mp4

Date
02/26/2018
W/O
690352
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00784
PipeID
P16149
Time
2:59 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5437
Sewer Name
21 SAN ANTONIO TRUNK
City
CLAREMONT
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
03
Purpose
Routine Assessment
Project
WO_690352_TV21055_MAR2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
21 1089
Downstream MH
21 1088
Dir. of Survey
Downstream
Length Surveyed
163.8 ft.
Total Length
163.8 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 21 1089 to 21 1088
MH: 21 1089MH: 21 1088downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 6 O'CLOCK0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 21 10892.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start10.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"59 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"87.2 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - Possible gap at bottom of connection.87.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"95.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"152 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"163.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish163.8 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK163.8 ft. AMH - Downstream Manhole, Survey Ends - 21 1088

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (14)

DistanceCodeObservation
0MWL
0MGOCONNECTION AT MH 6 O'CLOCK
163.8SAP
59TFC
87.2TFDPossible gap at bottom of connection.
0MWM
2.1SAP
87.2TF
152TFC
95.3TFC
10.6TFC
0AMH21 1089
163.8MGOCONNECTION AT MH 3 O'CLOCK
163.8AMH21 1088

Properties (4)

additional_info
SC347092
custom_field_two
2
customer
LACSD
datetime