Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 26, 2018, 11:16 AM
  • 21 1088_21 1087 _26022018_033425.mp4

Date
02/26/2018
W/O
690352
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00784
PipeID
P16148
Time
3:16 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5437
Sewer Name
21 SAN ANTONIO TRUNK
City
CLAREMONT
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
03
Purpose
Routine Assessment
Project
WO_690352_TV21055_MAR2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
21 1087
Downstream MH
21 1088
Dir. of Survey
Upstream
Length Surveyed
367.9 ft.
Total Length
367.9 ft.
Structural Index
3
Structural Quick
483N
Structural Rating
263
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
263
Pipe schematic from manhole 21 1087 to 21 1088
MH: 21 1087MH: 21 1088upstream0 ft. MGO - General Observation - CONNECTION AT MH 12 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 21 10880 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish18.4 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES18.4 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES, Finish24.7 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES, Start25.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES26.4 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: NO26.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"54.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES83.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"94.4 ft. FM - Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES114.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES120 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"175.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES176.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"204.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"227.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES237 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"265.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"272.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES289.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"308.7 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES313.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"337.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"357.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"361.2 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES365.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start367.9 ft. MWM - Water Mark, 35 %of cross sectional area367.9 ft. MWL - Water Level, 10 %of cross sectional area367.9 ft. AMH - Downstream Manhole, Survey Begins - 21 1087

Observation photos (13)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    6.7 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    59.2 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    95.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    140.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    192.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    253.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

    273.5 ft. - Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    313.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: NO

    341.5 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: NO

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    342.1 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES, Start

    343.2 ft. - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    349.5 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (32)

DistanceCodeObservation
247.9TFC
140.4FM
0MWM
284.4TFC
341.5FL
349.5FM
54.2TFC
102.8TF
2.1SAP
78.3TFC
0MWL
163.4TFC
0AMH21 1087
349.5FL
253.3FM
30.1TFC
343.2FL
191.6TFC
273.5FM
6.7FL
367.9MGOCONNECTION AT MH 12 O'CLOCK
313.6FM
367.9AMH21 1088
59.2FM
95.6FM
367.9MGOCONNECTION AT MH 3 O'CLOCK
367.9SAP
341.5TFC
342.1FL
130.9TFC
192.4FM
10.4TFC

Properties (4)

additional_info
SC347092
custom_field_two
2
customer
LACSD
datetime
2018-02-26T03:16:40-08:00