Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 10, 2016, 07:54 AM
  • 08 0270_08 0269 _08102016_010837.mp4

Date
08/10/2016
W/O
580478
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00004
PipeID
P00312
Time
12:54 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3631
Sewer Name
08 DEL AMO TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
08
Purpose
Routine Assessment
Project
WO_580478_TV08039_JULY2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
08 0270
Downstream MH
08 0269
Dir. of Survey
Downstream
Length Surveyed
352.2 ft.
Total Length
352.2 ft.
Structural Index
3
Structural Quick
4136
Structural Rating
24
O&M Index
2
O&M Quick
2M00
O&M Rating
140
Overall Index
2
Overall Quick
Overall Rating
164
Pipe schematic from manhole 08 0270 to 08 0269
MH: 08 0270MH: 08 0269downstream0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 02702 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start3.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES5.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES38.8 ft. CM - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES116.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"120 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"178.3 ft. CM - Crack Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES233.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"236.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"237.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES320.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"322.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES324 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"332.7 ft. CM - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES345.6 ft. FM - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES349.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish349.9 ft. MGO - General Observation - COCKROACHES IN MANHOLE352.2 ft. AMH - Downstream Manhole, Survey Ends - 08 0269

Observation photos (11)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    3.6 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    5.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

    38.8 ft. - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES

    178.3 ft. - Crack Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    237.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    322.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

    332.7 ft. - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

    345.6 ft. - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MANHOLE

    349.9 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (22)

DistanceCodeObservation
349.9DAGS
322.6CM
0MGOCOCKROACHES IN MANHOLE
324TFC
320.9TFC
3.6CL
352.2AMH08 0269
237.5CM
349.9MGOCOCKROACHES IN MANHOLE
2DAGS
236.4TFC
178.3CM
332.7CM
233.1TFC
0MWL
345.6FM
120TFC
0MWM
0AMH08 0270
116.8TFC
5.5CM
38.8CM

Properties (4)

additional_info
SC306065
custom_field_two
3
customer
LACSD
datetime
2016-08-10T00:54:05-07:00