Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 13, 2018, 06:12 PM
  • Section#1_B 0581_B 0580__3132018__G6969.mp4

Date
03/13/2018
W/O
0694143
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00104
PipeID
P09152
Time
11:12 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6969
Sewer Name
B JOINT OUTFALL B - UNIT 8A
City
EL MONTE
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
22
Purpose
Maintenance Related
Project
20180313DF_JOINT_OUTFALL_B_UNIT_8A
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Upstream MH
B 0581
Downstream MH
B 0580
Dir. of Survey
Downstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
5
Structural Quick
5300
Structural Rating
15
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
5
Overall Quick
Overall Rating
19
Pipe schematic from manhole B 0581 to B 0580
MH: B 0581MH: B 0580downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 11:25 AM2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES2 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES - 75% MAG2 ft. LD - Alignment Down, 45 %2.1 ft. MSA - Survey Abandoned - HIGH WATER

Observation photos (3)

  • Water Mark, 40 %of cross sectional area

    0 ft. - Water Mark, 40 %of cross sectional area

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Alignment Down, 45 %

    2 ft. - Alignment Down, 45 %

Observations (7)

DistanceCodeObservation
0MWM
0MWL
0AMH11:25 AM
2SRV
2.1MSAHIGH WATER
2SZ75% MAG
2LD

Properties (4)

additional_info
DOWNLEG VIEW OF THE U/S SIPHON
custom_field_two
5
customer
LACSD
datetime
2018-03-13T11:12:45-07:00