Section#1_05 2082_05 2081__3122018__G6964.mp4
2 ft. - General Observation - 100% MAG COAT 8:00 TO 4:00
16.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE-POSSIBLE
16.7 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG UNDER MAG COAT POSSIBLE
44.6 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
213.5 ft. - General Observation - 100% MAG COAT
327.3 ft. - Surface Spalling, from 11 to 12 o'clock, within 8 inches of joint: NO - BLISTERING CONCETE UNDER MAG COAT
446.7 ft. - Surface Aggregate Visible, from 11 to 12 o'clock, within 8 inches of joint: NO - SEVERE AGG
557.4 ft. - General Observation - 100% MAG COAT
| Distance | Code | Observation |
|---|---|---|
| 0 | MWM | — |
| 728.1 | MGO | MH 2081 CAR ON MH SETUP AT MH 2080 |
| 213.5 | MGO | 100% MAG COAT |
| 2 | MGO | 100% MAG COAT 8:00 TO 4:00 |
| 327.3 | SSS | BLISTERING CONCETE UNDER MAG COAT |
| 16.6 | SSS | BLISTERING PEELING CONCRETE-POSSIBLE |
| 728.1 | MGO | 100% MAG COAT FINISH |
| 0 | MWL | — |
| 16.7 | SAV | SEVERE AGG UNDER MAG COAT POSSIBLE |
| 728.1 | SSS | BLISTERING PEELING CONCRETE UNDER MAG COAT -POSSIBLE |
| 728.8 | AMH | 2:35AM |
| 44.6 | DAGS | — |
| 0 | AMH | 1:15AM |
| 728.1 | SAV | SEVERE AGG UNDER MAG COAT POSSIBLE |
| 446.7 | SAV | SEVERE AGG |
| 557.4 | MGO | 100% MAG COAT |
| 728.1 | DAGS | — |