Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 10, 2018, 08:46 AM
  • C 0314_C 0313A_3102018_020850.mp4

Date
03/10/2018
W/O
0693749
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00135
PipeID
P09777
Time
12:46 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0772
Sewer Name
C JOINT OUTFALL C - UNIT 6F
City
CERRITOS
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
04
Purpose
Capital Improvement Program Assesment
Project
20180310MDM_JOINT_OUTFALL_C_UNIT_6F
Material
Reinforced Concrete Pipe
Shape
Circular
Height
15 in.
Upstream MH
C 0314
Downstream MH
C 0313A
Dir. of Survey
Downstream
Length Surveyed
377.9 ft.
Total Length
377.9 ft.
Structural Index
4
Structural Quick
5C34
Structural Rating
113
O&M Index
2
O&M Quick
2400
O&M Rating
8
Overall Index
4
Overall Quick
Overall Rating
121
Pipe schematic from manhole C 0314 to C 0313A
MH: C 0314MH: C 0313Adownstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:05AM0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE2.5 ft. MGO - General Observation - MAG COAT 95% START 8:00 MTO 4;0023.1 ft. SAV - Surface Aggregate Visible, from 08 to 12 o'clock, within 8 inches of joint: YES - SEVERE AGG23.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE23.7 ft. MGO - General Observation - MAG COAT FINISH26 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG128 ft. DAE - Deposits Attached Encrustation, 3 %of cross sectional area, from 01 to 05 o'clock, , within 8 inches of joint: YES128.5 ft. SRV - Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: YES - LONG CIRCUM137.2 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 08 to 11 o'clock, , within 8 inches of joint: YES137.2 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: YES, 6" - Open139.2 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 02 to 04 o'clock, , within 8 inches of joint: YES139.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open144 ft. DAE - Deposits Attached Encrustation, 3 %of cross sectional area, from 02 to 05 o'clock, , within 8 inches of joint: YES144.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG161 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open163.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE167.3 ft. SRV - Surface Reinforcement Visible, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR172.4 ft. SRV - Surface Reinforcement Visible, from 12 to 03 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR187.6 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO - LONG201.7 ft. SRC - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR216.2 ft. SRC - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR275.6 ft. SRV - Surface Reinforcement Visible, from 02 to 04 o'clock, within 8 inches of joint: YES - CIRCUM277.3 ft. SRC - Surface Reinforcement Corroded, from 08 to 11 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR281.5 ft. SRC - Surface Reinforcement Corroded, from 08 to 11 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM283.3 ft. SRV - Surface Reinforcement Visible, from 12 to 04 o'clock, within 8 inches of joint: YES, Start - CIRCUM288.3 ft. SRC - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: YES - LONG290.7 ft. SRV - Surface Reinforcement Visible, from 12 to 04 o'clock, within 8 inches of joint: YES, Finish - CIRCUM290.7 ft. SRV - Surface Reinforcement Visible, from 08 to 10 o'clock, within 8 inches of joint: YES - LONG CIRCUM300.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG300.1 ft. SRV - Surface Reinforcement Visible, at 11 o'clock, within 8 inches of joint: YES, Start - LONG306.5 ft. SRV - Surface Reinforcement Visible, from 12 to 03 o'clock, within 8 inches of joint: YES - LONG CIRCUM308 ft. SRV - Surface Reinforcement Visible, at 11 o'clock, within 8 inches of joint: YES, Finish - LONG324.5 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - CIRCUM327.7 ft. SRV - Surface Reinforcement Visible, at 11 o'clock, within 8 inches of joint: NO - LONG330.8 ft. SRV - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: NO - CIRCUM333.6 ft. SRV - Surface Reinforcement Visible, from 08 to 12 o'clock, within 8 inches of joint: YES, Start - LOMG CIRCUM333.6 ft. SRV - Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: NO - CIRCUM340.5 ft. SRV - Surface Reinforcement Visible, from 08 to 12 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM345.2 ft. SRV - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO - LOMG350.4 ft. SRV - Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: YES - CIRCUM375.9 ft. SRC - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR377.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG377.6 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active377.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE377.9 ft. AMH - Downstream Manhole, Survey Ends - 3:00AM

Observation photos (26)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • General Observation - MAG COAT 95% START 8:00 MTO 4;00

    2.5 ft. - General Observation - MAG COAT 95% START 8:00 MTO 4;00

  • Surface Aggregate Visible, from 08 to 12 o'clock, within 8 inches of joint: YES - SEVERE AGG

    23.1 ft. - Surface Aggregate Visible, from 08 to 12 o'clock, within 8 inches of joint: YES - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE

    23.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE

  • General Observation - MAG COAT FINISH

    23.7 ft. - General Observation - MAG COAT FINISH

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG

    26 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG

  • Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: YES - LONG CIRCUM

    128.5 ft. - Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: YES - LONG CIRCUM

  • Deposits Attached Grease, 10 %of cross sectional area, from 08 to 11 o'clock,  , within 8 inches of joint: YES

    137.2 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 08 to 11 o'clock, , within 8 inches of joint: YES

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 02 to 04 o'clock,  , within 8 inches of joint: YES

    139.2 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 02 to 04 o'clock, , within 8 inches of joint: YES

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

    144.9 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE

    163.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE

  • Surface Reinforcement Visible, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

    167.3 ft. - Surface Reinforcement Visible, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

  • Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO - LONG

    187.6 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO - LONG

  • Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

    201.7 ft. - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

  • Surface Reinforcement Visible, from 02 to 04 o'clock, within 8 inches of joint: YES - CIRCUM

    275.6 ft. - Surface Reinforcement Visible, from 02 to 04 o'clock, within 8 inches of joint: YES - CIRCUM

  • Surface Reinforcement Corroded, from 08 to 11 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

    277.3 ft. - Surface Reinforcement Corroded, from 08 to 11 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

  • Surface Reinforcement Visible, from 12 to 04 o'clock, within 8 inches of joint: YES, Start - CIRCUM

    283.3 ft. - Surface Reinforcement Visible, from 12 to 04 o'clock, within 8 inches of joint: YES, Start - CIRCUM

  • Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: YES - LONG

    288.3 ft. - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: YES - LONG

  • Surface Reinforcement Visible, from 08 to 10 o'clock, within 8 inches of joint: YES - LONG CIRCUM

    290.7 ft. - Surface Reinforcement Visible, from 08 to 10 o'clock, within 8 inches of joint: YES - LONG CIRCUM

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

    300.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Reinforcement Visible, at 11 o'clock, within 8 inches of joint: YES, Start - LONG

    300.1 ft. - Surface Reinforcement Visible, at 11 o'clock, within 8 inches of joint: YES, Start - LONG

  • Surface Reinforcement Visible, from 12 to 03 o'clock, within 8 inches of joint: YES -  LONG CIRCUM

    306.5 ft. - Surface Reinforcement Visible, from 12 to 03 o'clock, within 8 inches of joint: YES - LONG CIRCUM

  • Surface Reinforcement Visible, from 08 to 12 o'clock, within 8 inches of joint: YES, Start - LOMG CIRCUM

    333.6 ft. - Surface Reinforcement Visible, from 08 to 12 o'clock, within 8 inches of joint: YES, Start - LOMG CIRCUM

  • Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO - LOMG

    345.2 ft. - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO - LOMG

  • Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: YES - CIRCUM

    350.4 ft. - Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: YES - CIRCUM

  • Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR

    375.9 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR

Observations (48)

DistanceCodeObservation
308SRVLONG
137.2DAGS
201.7SRCLONG CIRCUM REBAR
377.6SAPSEVERE AGG
23.7MGOMAG COAT FINISH
275.6SRVCIRCUM
139.2DAE
0MWM
2.5MGOMAG COAT 95% START 8:00 MTO 4;00
290.7SRVCIRCUM
377.9AMH3:00AM
340.5SRVLONG CIRCUM
306.5SRVLONG CIRCUM
300.1SAPSEVERE AGG
2SSSBLISTERING PEELING CONCRETE
350.4SRVCIRCUM
277.3SRCLONG CIRCUM REBAR
139.2TFOpen
128DAE
377.6MGOConn. @ Mh, 9 O' Clock. Active
0AMH2:05AM
333.6SRVLOMG CIRCUM
26SAPSEVERE AGG
324.5SRVCIRCUM
327.7SRVLONG
288.3SRCLONG
23.1SAVSEVERE AGG
0MWL
333.6SRVCIRCUM
377.6SSSBLISTERING PEELING CONCRETE
281.5SRCLONG CIRCUM
137.2TBOpen
144.9SAPSEVERE AGG
128.5SRVLONG CIRCUM
144DAE
172.4SRVLONG CIRCUM REBAR
187.6SRVLONG
163.1SSSPEELING CONCRETE
167.3SRVLONG CIRCUM REBAR
330.8SRVCIRCUM
375.9SRCLONG CIRCUM REBAR
300.1SRVLONG
216.2SRCLONG CIRCUM REBAR
345.2SRVLOMG
283.3SRVCIRCUM
23.1SSSPEELING CONCRETE
290.7SRVLONG CIRCUM
161TFOpen

Properties (4)

custom_field_three
CORRODED LONG CIRCUM REBAR
custom_field_two
2
customer
LACSD
datetime
2018-03-10T00:46:53-08:00