Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 10, 2018, 08:37 AM
  • C 0315_C 0314_3102018_005159.mp4

Date
03/10/2018
W/O
0693749
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00135
PipeID
P09778
Time
12:37 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0772
Sewer Name
C JOINT OUTFALL C - UNIT 6F
City
CERRITOS
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
04
Purpose
Capital Improvement Program Assesment
Project
20180310MDM_JOINT_OUTFALL_C_UNIT_6F
Material
Reinforced Concrete Pipe
Shape
Circular
Height
15 in.
Upstream MH
C 0314
Downstream MH
C 0315
Dir. of Survey
Upstream
Length Surveyed
356.7 ft.
Total Length
356.7 ft.
Structural Index
4
Structural Quick
5B34
Structural Rating
90
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
90
Pipe schematic from manhole C 0314 to C 0315
MH: C 0314MH: C 0315upstream0 ft. AMH - Upstream Manhole, Survey Ends - 1:45AM0.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE0.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE24.4 ft. SRV - Surface Reinforcement Visible, from 09 to 12 o'clock, within 8 inches of joint: YES, Finish - CIRCUM24.4 ft. SRV - Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: YES, Finish - LONG31.2 ft. SRC - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Finish - CIRCUM33.2 ft. SRV - Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: YES, Start - LONG40.6 ft. SRV - Surface Reinforcement Visible, from 09 to 12 o'clock, within 8 inches of joint: YES, Start - CIRCUM48.5 ft. TB - Tap Break-In, at 09 o'clock, -, within 8 inches of joint: YES, 6" - Active49.1 ft. SRC - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM66.3 ft. SRC - Surface Reinforcement Corroded, at 01 o'clock, within 8 inches of joint: NO - LONG103.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open106.5 ft. SRV - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO - LONG154 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open175.6 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM193 ft. SRC - Surface Reinforcement Corroded, from 10 to 03 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM193 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM199.1 ft. SRC - Surface Reinforcement Corroded, from 10 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM203.3 ft. SAV - Surface Aggregate Visible, from 02 to 03 o'clock, within 8 inches of joint: NO - CIRCUM206.9 ft. SAV - Surface Aggregate Visible, from 01 to 02 o'clock, within 8 inches of joint: NO - CIRCUM244 ft. SRV - Surface Reinforcement Visible, from 12 to 04 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM244 ft. SRV - Surface Reinforcement Visible, at 02 o'clock, within 8 inches of joint: YES, Finish - LONG257.8 ft. SRV - Surface Reinforcement Visible, from 12 to 04 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM259.5 ft. SRV - Surface Reinforcement Visible, at 02 o'clock, within 8 inches of joint: YES, Start - LONG287.8 ft. FC - Fracture Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES - CIRCUM289.6 ft. SRV - Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: YES - LONG292.6 ft. SRV - Surface Reinforcement Visible, from 02 to 04 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM297.2 ft. SRV - Surface Reinforcement Visible, from 10 to 04 o'clock, within 8 inches of joint: NO - LONG CIRCUM302.4 ft. SRV - Surface Reinforcement Visible, from 10 to 04 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR306 ft. SRV - Surface Reinforcement Visible, from 02 to 04 o'clock, within 8 inches of joint: YES, - CIRCUM311.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open312.8 ft. SRV - Surface Reinforcement Visible, at 02 o'clock, within 8 inches of joint: YES, Finish - LONG316 ft. SRV - Surface Reinforcement Visible, at 02 o'clock, within 8 inches of joint: YES, Start - LONG REBAR331 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE331 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE334.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE352.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG354.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG356.7 ft. MWL - Water Level, 10 %of cross sectional area356.7 ft. AMH - Downstream Manhole, Survey Begins - 12:45AM356.7 ft. MWM - Water Mark, 20 %of cross sectional area

Observation photos (21)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG

    4 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    22.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE

    25.7 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

    25.7 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

  • Surface Reinforcement Visible, at 02 o'clock, within 8 inches of joint: YES, Start - LONG REBAR

    40.7 ft. - Surface Reinforcement Visible, at 02 o'clock, within 8 inches of joint: YES, Start - LONG REBAR

  • Surface Reinforcement Visible, from 02 to 04 o'clock, within 8 inches of joint: YES,  - CIRCUM

    50.7 ft. - Surface Reinforcement Visible, from 02 to 04 o'clock, within 8 inches of joint: YES, - CIRCUM

  • Surface Reinforcement Visible, from 10 to 04 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

    54.3 ft. - Surface Reinforcement Visible, from 10 to 04 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

  • Surface Reinforcement Visible, from 10 to 04 o'clock, within 8 inches of joint: NO - LONG CIRCUM

    59.5 ft. - Surface Reinforcement Visible, from 10 to 04 o'clock, within 8 inches of joint: NO - LONG CIRCUM

  • Fracture Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES - CIRCUM

    68.9 ft. - Fracture Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES - CIRCUM

  • Surface Reinforcement Visible, at 02 o'clock, within 8 inches of joint: YES, Start - LONG

    97.2 ft. - Surface Reinforcement Visible, at 02 o'clock, within 8 inches of joint: YES, Start - LONG

  • Surface Reinforcement Visible, from 12 to 04 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM

    98.9 ft. - Surface Reinforcement Visible, from 12 to 04 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM

  • Surface Aggregate Visible, from 01 to 02 o'clock, within 8 inches of joint: NO - CIRCUM

    149.8 ft. - Surface Aggregate Visible, from 01 to 02 o'clock, within 8 inches of joint: NO - CIRCUM

  • Surface Reinforcement Corroded, from 10 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM

    157.6 ft. - Surface Reinforcement Corroded, from 10 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM

  • Surface Reinforcement Corroded, from 10 to 03 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM

    163.7 ft. - Surface Reinforcement Corroded, from 10 to 03 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM

    163.7 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM

  • Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO - LONG

    250.2 ft. - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO - LONG

  • Surface Reinforcement Corroded, at 01 o'clock, within 8 inches of joint: NO - LONG

    290.4 ft. - Surface Reinforcement Corroded, at 01 o'clock, within 8 inches of joint: NO - LONG

  • Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM

    307.6 ft. - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM

  • Surface Reinforcement Visible, from 09 to 12 o'clock, within 8 inches of joint: YES, Start - CIRCUM

    316.1 ft. - Surface Reinforcement Visible, from 09 to 12 o'clock, within 8 inches of joint: YES, Start - CIRCUM

  • Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: YES, Start - LONG

    323.5 ft. - Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: YES, Start - LONG

Observations (41)

DistanceCodeObservation
316.1SRVCIRCUM
25.7SSSPEELING CONCRETE
250.2SRVLONG
332.3SRVCIRCUM
308.2TBActive
64.1SRVLONG CIRCUM
163.7SRCLONG CIRCUM
97.2SRVLONG
22.3SSSBLISTERING PEELING CONCRETE
252.8TFOpen
54.3SRVLONG CIRCUM REBAR
2SAPSEVERE AGG
356.7AMH1:45AM
149.8SAVCIRCUM
67.1SRVLONG
202.7TFOpen
290.4SRCLONG
323.5SRVLONG
112.7SRVLONG CIRCUM
44.8TFOpen
112.7SRVLONG
68.9FCCIRCUM
356.4SAPSEVERE
43.9SRVLONG
0MWL
325.5SRCCIRCUM
0AMH12:45AM
50.7SRVCIRCUM
153.4SAVCIRCUM
332.3SRVLONG
307.6SRCCIRCUM
157.6SRCLONG CIRCUM
59.5SRVLONG CIRCUM
163.7SRVLONG CIRCUM
4SAPSEVERE AGG
0MWM
40.7SRVLONG REBAR
25.7SSSBLISTERING PEELING CONCRETE
98.9SRVLONG CIRCUM
181.1SRVLONG CIRCUM
356.4SSSBLISTERING PEELING CONCRETE

Properties (5)

additional_info
REVERSE INSPECTION
custom_field_three
CORRODED LONG CIRCUM REBAR
custom_field_two
2
customer
LACSD
datetime
2018-03-10T00:37:13-08:00