Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 2, 2015, 11:29 AM
  • 20 0051_20 0050_20150302_045602.mp4

Date
03/02/2015
W/O
491612
Weather
Light Rain
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00742
PipeID
P18972
Time
3:29 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2138
Sewer Name
20 TRUNK "A"
City
PALMDALE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 20
Page No.
03
Purpose
Routine Assessment
Project
WO_491612_TV20026_2015FEBRUARY
Sewer Type
GRAVITY
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
20 0051
Downstream MH
20 0050
Dir. of Survey
Downstream
Length Surveyed
342.9 ft.
Total Length
342.9 ft.
Structural Index
3
Structural Quick
543J
Structural Rating
179
O&M Index
2
O&M Quick
2J00
O&M Rating
106
Overall Index
3
Overall Quick
Overall Rating
285
Pipe schematic from manhole 20 0051 to 20 0050
MH: 20 0051MH: 20 0050downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 9 O' CLOCK0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 20 00512 ft. MGO - General Observation - Magnesium hydroxide coating 80% start30.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"44.1 ft. SRC - Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: YES63.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"67.5 ft. SRC - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: YES76.3 ft. SAV - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start76.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start111.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"125.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"145.9 ft. SRC - Surface Reinforcement Corroded, from 10 to 11 o'clock, within 8 inches of joint: YES167.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"215.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"238.9 ft. SRV - Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: YES263.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"319.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"339.4 ft. SAV - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish339.4 ft. MGO - General Observation - Magnesium hydroxide coating 80% finish339.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish342.9 ft. AMH - Downstream Manhole, Survey Ends - 20 0050

Observation photos (6)

  • Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: YES

    44.1 ft. - Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: YES

    67.5 ft. - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: YES

  • Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

    76.3 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    76.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Reinforcement Corroded, from 10 to 11 o'clock, within 8 inches of joint: YES

    145.9 ft. - Surface Reinforcement Corroded, from 10 to 11 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: YES

    238.9 ft. - Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: YES

Observations (23)

DistanceCodeObservation
0MWM
67.5SRC
0MGOCONNECTION AT THE MH 9 O' CLOCK
44.1SRC
76.7DAGS
238.9SRV
0MWL
0AMH20 0051
263.4TFC
339.4SAV
111.2TFC
145.9SRC
2MGOMagnesium hydroxide coating 80% start
339.4MGOMagnesium hydroxide coating 80% finish
215.2TFC
339.4DAGS
30.8TFC
319.8TFC
342.9AMH20 0050
63.5TFC
76.3SAV
167.5TFC
125.1TFA

Properties (4)

additional_info
SC207714
custom_field_two
2
customer
LACSD
datetime
2015-03-02T03:29:31-08:00