Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 6, 2018, 08:57 AM
  • H 0267_H 0266_362018_013624.mp4

Date
03/06/2018
W/O
0693760
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00173
PipeID
P10719
Time
12:57 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0766
Sewer Name
H JOINT OUTFALL H - UNIT 2H
City
VERNON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 23
Page No.
02
Purpose
Maintenance Related
Project
20180306MDM_JOINT_OUTFALL_H_UNIT_2H
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
H 0267
Downstream MH
H 0266
Dir. of Survey
Downstream
Length Surveyed
406.6 ft.
Total Length
406.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole H 0267 to H 0266
MH: H 0267MH: H 0266downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:35AM0 ft. MWL - Water Level, 10 %of cross sectional area77.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped114.3 ft. MGO - General Observation - 18" VCP141.4 ft. MGO - General Observation - 18" VCP155.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped228.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open305.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped373 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped406.2 ft. MGO - General Observation - NO MISSING PIPE IN REACH406.2 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Capped406.6 ft. AMH - Downstream Manhole, Survey Ends - 1:50AM

Observation photos (2)

  • General Observation - 18" VCP

    114.3 ft. - General Observation - 18" VCP

  • General Observation - 18" VCP

    141.4 ft. - General Observation - 18" VCP

Observations (13)

DistanceCodeObservation
77.8TFCCapped
406.2MGONO MISSING PIPE IN REACH
0MWM
305.7TFCCapped
406.6AMH1:50AM
0AMH1:35AM
114.3MGO18" VCP
228.6TFOpen
141.4MGO18" VCP
373TFCCapped
155.6TFCCapped
0MWL
406.2MGOConn. @ Mh, 9 O' Clock. Capped

Properties (2)

customer
LACSD
datetime
2018-03-06T00:57:18-08:00