Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 6, 2018, 08:45 AM
  • H 0268_H 0267_362018_010529.mp4

Date
03/06/2018
W/O
0693760
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00173
PipeID
P10720
Time
12:45 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0766
Sewer Name
H JOINT OUTFALL H - UNIT 2H
City
VERNON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 23
Page No.
02
Purpose
Maintenance Related
Project
20180306MDM_JOINT_OUTFALL_H_UNIT_2H
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
H 0267
Downstream MH
H 0268
Dir. of Survey
Upstream
Length Surveyed
388.7 ft.
Total Length
388.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3121
O&M Rating
5
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole H 0267 to H 0268
MH: H 0267MH: H 0268upstream0 ft. AMH - Upstream Manhole, Survey Ends - 1:15AM0.3 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Capped0.3 ft. MGO - General Observation - NO MISSING PIPE IN REACH0.3 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Capped85.6 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open-95% GREASE159.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open163.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped236.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped279.8 ft. DAZ - Deposits Attached Other, 15 %of cross sectional area, from 01 to 05 o'clock, , within 8 inches of joint: YES, Finish - GREASE OR SCALE313 ft. DAZ - Deposits Attached Other, 15 %of cross sectional area, from 01 to 05 o'clock, , within 8 inches of joint: YES, Start - GREASE OR SCALE313 ft. MGP - General Photograph - GREASE OR SCALE BUILD UP313 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped388.7 ft. MWM - Water Mark, 20 %of cross sectional area388.7 ft. MWL - Water Level, 10 %of cross sectional area388.7 ft. AMH - Downstream Manhole, Survey Begins - 12:55AM

Observation photos (2)

  • Deposits Attached Other, 15 %of cross sectional area, from 01 to 05 o'clock,  , within 8 inches of joint: YES, Start - GREASE OR SCALE

    75.7 ft. - Deposits Attached Other, 15 %of cross sectional area, from 01 to 05 o'clock, , within 8 inches of joint: YES, Start - GREASE OR SCALE

  • General Photograph - GREASE OR SCALE BUILD UP

    75.7 ft. - General Photograph - GREASE OR SCALE BUILD UP

Observations (15)

DistanceCodeObservation
0MWM
388.4MGOConn. @ Mh, 3 O' Clock. Capped
75.7DAZGREASE OR SCALE
75.7MGPGREASE OR SCALE BUILD UP
228.8TFOpen
303.1TFDOpen-95% GREASE
108.9DAZGREASE OR SCALE
225.5TFCCapped
0MWL
388.7AMH1:15AM
75.7TFCCapped
152.5TFCCapped
388.4MGONO MISSING PIPE IN REACH
0AMH12:55AM
388.4MGOConn. @ Mh, 9 O' Clock. Capped

Properties (3)

additional_info
REVERSE INSPECTION-LOOKING FOR MISSING PIPE
customer
LACSD
datetime
2018-03-06T00:45:05-08:00