Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 15, 2018, 05:37 PM
  • 08 0372_08 0371_2152018_093956.mp4

Date
02/15/2018
W/O
0690350
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00003
PipeID
P00425
Time
9:37 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7633
Sewer Name
08 DAVIDSON CITY TRUNK, SECTS 1,2,&3
City
CARSON
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
12
Purpose
Routine Assessment
Project
20180215DF_DAVIDSON_CITY_TR_SECTS_1_2_3
Material
NRCP
Shape
Circular
Height
18 in.
Upstream MH
08 0372
Downstream MH
08 0373
Dir. of Survey
Upstream
Length Surveyed
145 ft.
Total Length
145 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 08 0372 to 08 0373
MH: 08 0372MH: 08 0373upstream0 ft. AMH - Upstream Manhole, Survey Ends - 9:51 AM4.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish4.5 ft. MGO - General Observation - Grease Throughout The Reach (5%)49.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"82.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"106.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"119.5 ft. MGP - General Photograph - INTRUDING CONN. .5"119.5 ft. TFD - Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: YES, 4" - Open143 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start145 ft. MWL - Water Level, 20 %of cross sectional area145 ft. AMH - Downstream Manhole, Survey Begins - 9:38 AM145 ft. MWM - Water Mark, 25 %of cross sectional area145 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active

Observation photos (3)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph - INTRUDING CONN. .5"

    25.5 ft. - General Photograph - INTRUDING CONN. .5"

  • Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: YES, 4" - Open

    25.5 ft. - Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: YES, 4" - Open

Observations (13)

DistanceCodeObservation
145AMH9:51 AM
0MWL
25.5MGPINTRUDING CONN. .5"
0AMH9:38 AM
38.2TFC
2SSS
140.5SSS
0MWM
0MGOConn. @ Mh, 3 O' Clock. Active
25.5TFDOpen
62.2TFC
140.5MGOGrease Throughout The Reach (5%)
95.7TFC

Properties (4)

additional_info
PIPE ID ON SCREEN IS WRONG. CORRECT ID # IS (P00425)
custom_field_two
3
customer
LACSD
datetime
2018-02-15T09:37:32-08:00