Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 6, 2018, 10:29 AM
  • 01 1127_01 1126_06022018_031822.mp4

Date
02/06/2018
W/O
685073
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00210
PipeID
P01979
Time
2:29 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5432
Sewer Name
01 HUNTINGTON PARK TRUNK
City
HUNTINGTON PARK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
04
Purpose
Routine Assessment
Project
WO_685073_TV01246_FEB2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 1127
Downstream MH
01 1126
Dir. of Survey
Downstream
Length Surveyed
288.6 ft.
Total Length
288.6 ft.
Structural Index
3
Structural Quick
413J
Structural Rating
175
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
178
Pipe schematic from manhole 01 1127 to 01 1126
MH: 01 1127MH: 01 1126downstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MGO - General Observation - CONNECTION AT MH 6 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 01 11270 ft. MWL - Water Level, 5 %of cross sectional area0.1 ft. MWM - Water Mark, 15 %of cross sectional area3.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES5.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start18.9 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"70.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"74.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"74.5 ft. RML - Roots Medium Lateral, at 10 o'clock, 20 %, within 8 inches of joint: NO113.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"123.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"152.1 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6", 6"164.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"190.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"200 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"246.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"258 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"284.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"288 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish288.6 ft. AMH - Downstream Manhole, Survey Ends - 01 1126

Observation photos (2)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    3.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (23)

DistanceCodeObservation
152.1TFA
0MGOCONNECTION AT MH 3 O'CLOCK
0MGOCONNECTION AT MH 9 O'CLOCK
164.7TF
0.1MWM
3.2FM
200TF
0MGOCONNECTION AT MH 6 O'CLOCK
5.3CM
246.6TF
284.9TF
18.9TB
113.7TF
74.5RML
288.6AMH01 1126
123.5TF
258TF
288CM
70.9TF
190.3TF
0AMH01 1127
0MWL
74.4TF

Properties (4)

additional_info
SC347070
custom_field_two
3
customer
LACSD
datetime
2018-02-06T02:29:00-08:00