- Date
- 02/13/2018
- W/O
- 679239
- Weather
- Light Rain
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00485
- PipeID
- P06824
- Time
- 12:02 AM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5403
- Sewer Name
- 05 MARICOPA STREET TRUNK
- City
- TORRANC
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 25
- Purpose
- Routine Assessment
- Project
- WO_679239_TV05070_JAN2018
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 10 in.
- Width
- 10 in.
- Upstream MH
- 05 1600
- Downstream MH
- 05 1599
- Dir. of Survey
- Downstream
- Length Surveyed
- 312.2 ft.
- Total Length
- 312.2 ft.
- Structural Index
- 3
- Structural Quick
- 3K2K
- Structural Rating
- 302
- O&M Index
- 2
- O&M Quick
- 5112
- O&M Rating
- 7
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 309
Pipe schematic from manhole 05 1600 to 05 1599 Observation photos (3)

2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

21.2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

282.1 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start