Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 4, 2018, 10:19 AM
  • 05 1598_05 1597 _04012018_024242.mp4

Date
01/04/2018
W/O
679239
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00485
PipeID
P06822
Time
2:19 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5172
Sewer Name
05 MARICOPA STREET TRUNK
City
TORRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
26
Purpose
Routine Assessment
Project
WO_679239_TV05070_JAN2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
05 1598
Downstream MH
05 1597
Dir. of Survey
Downstream
Length Surveyed
342.7 ft.
Total Length
342.7 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 05 1598 to 05 1597
MH: 05 1598MH: 05 1597downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 15980 ft. MWL - Water Level, 10 %of cross sectional area2.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start27 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"31.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"75.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"79.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"135.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"140 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"192.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"196.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"249.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"252.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"301.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4", 4"305.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"340.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish340.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish342.7 ft. AMH - Downstream Manhole, Survey Ends - 05 1597342.7 ft. MGO - General Observation - CONNECTION AT MH 9 OCLOCK

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.4 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (21)

DistanceCodeObservation
249.1TF
27TF
196.7TFC
140TFC
301.3TF
252.9TFC
342.7AMH05 1597
79.7TFC
192.8TFC
0MWM
340.2SAV
0AMH05 1598
2.4SAV
305.5TFC
340.2DAGS
342.7MGOCONNECTION AT MH 9 OCLOCK
2.4DAGS
31.4TF
135.9TFC
75.5TFC
0MWL

Properties (4)

additional_info
SC350390
custom_field_two
3
customer
LACSD
datetime
2018-01-04T02:19:50-08:00