Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 5, 2018, 09:36 AM
  • 05 0655_05 0654 _05012018_015529.mp4

Date
01/05/2018
W/O
679249
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00520
PipeID
P05880
Time
1:36 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5307
Sewer Name
05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK
City
INGLEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
10
Purpose
Routine Assessment
Project
WO_679249_TV05103_JAN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
05 0655
Downstream MH
05 0654
Dir. of Survey
Downstream
Length Surveyed
349.5 ft.
Total Length
349.5 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
1
O&M Quick
2112
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 05 0655 to 05 0654
MH: 05 0655MH: 05 0654downstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK ACTIVE0 ft. VC - Vermin Cockroach0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK CAPPED0 ft. AMH - Upstream Manhole, Survey Begins - 05 06550 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area3.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start78.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4"87.5 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES121 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"166.2 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"214.9 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"263.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"314.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"349.5 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK ACTIVE349.5 ft. VC - Vermin Cockroach349.5 ft. AMH - Downstream Manhole, Survey Ends - 05 0654349.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish349.5 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK CAPPED

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    3.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    87.5 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

Observations (19)

DistanceCodeObservation
349.5MGOCONNECTION AT MH 3 O'CLOCK ACTIVE
0MGOCONNECTION AT MH 3 O'CLOCK ACTIVE
214.9TFA
3.2DAGS
349.5VC
166.2TFA
349.5AMH05 0654
0VC
349.5DAGS
349.5MGOCONNECTION AT MH 9 O'CLOCK CAPPED
0MGOCONNECTION AT MH 9 O'CLOCK CAPPED
121TFC
78.7TF
87.5CL
0AMH05 0655
263.3TFC
0MWL
314.6TFC
0MWM

Properties (4)

additional_info
SC346901
custom_field_two
4
customer
LACSD
datetime
2018-01-05T01:36:50-08:00