Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 11, 2018, 11:34 AM
  • 05 0650_05 0649 _11012018_034539.mp4

Date
01/11/2018
W/O
679249
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00520
PipeID
P05875
Time
3:34 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5371
Sewer Name
05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK
City
INGLEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
10
Purpose
Routine Assessment
Project
WO_679249_TV05103_JAN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
05 0649
Downstream MH
05 0650
Dir. of Survey
Upstream
Length Surveyed
66.7 ft.
Total Length
66.7 ft.
Structural Index
3
Structural Quick
3400
Structural Rating
12
O&M Index
2
O&M Quick
412B
O&M Rating
30
Overall Index
2
Overall Quick
Overall Rating
42
Pipe schematic from manhole 05 0649 to 05 0650
MH: 05 0649MH: 05 0650upstream0 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish0 ft. MSA - Survey Abandoned - REVERSAL COMPLETE.0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish21.7 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start33.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"64.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start66.7 ft. MWM - Water Mark, 50 %of cross sectional area66.7 ft. MWL - Water Level, 25 %of cross sectional area66.7 ft. AMH - Downstream Manhole, Survey Begins - 05 0649

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    45 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Survey Abandoned - REVERSAL COMPLETE.

    66.7 ft. - Survey Abandoned - REVERSAL COMPLETE.

Observations (9)

DistanceCodeObservation
66.7CM
0MWM
66.7MSAREVERSAL COMPLETE.
45CM
0MWL
2DAGS
66.7DAGS
0AMH05 0649
33.1TFC

Properties (4)

additional_info
SC346448
custom_field_two
4
customer
LACSD
datetime
2018-01-11T03:34:12-08:00