Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 4, 2018, 11:39 AM
  • 05 0664_05 0663 _04012018_035336.mp4

Date
01/04/2018
W/O
679249
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00520
PipeID
P05889
Time
3:39 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5306
Sewer Name
05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK
City
INGLEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
10
Purpose
Routine Assessment
Project
WO_679249_TV05103_JAN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
05 0664
Downstream MH
05 0663
Dir. of Survey
Downstream
Length Surveyed
333.2 ft.
Total Length
333.2 ft.
Structural Index
2
Structural Quick
2A00
Structural Rating
20
O&M Index
2
O&M Quick
2L11
O&M Rating
133
Overall Index
2
Overall Quick
Overall Rating
153
Pipe schematic from manhole 05 0664 to 05 0663
MH: 05 0664MH: 05 0663downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 06642.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start4.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start13.1 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"50.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish52.4 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"88.7 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"152.7 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"207.2 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"227 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"261.5 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES274.8 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"305.4 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"333.2 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK ACTIVE333.2 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK ACTIVE333.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish333.2 ft. VC - Vermin Cockroach333.2 ft. AMH - Downstream Manhole, Survey Ends - 05 0663

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    261.5 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

Observations (20)

DistanceCodeObservation
333.2MGOCONNECTION AT MH 9 O'CLOCK ACTIVE
152.7TFA
261.5CL
13.1TFA
2.1DAGS
274.8TFA
88.7TFA
207.2TFA
4.3SSS
333.2MGOCONNECTION AT MH 3 O'CLOCK ACTIVE
0MWM
52.4TFA
333.2DAGS
333.2VC
0MWL
333.2AMH05 0663
227TBA
0AMH05 0664
50.6SSS
305.4TFA

Properties (4)

additional_info
SC346475
custom_field_two
4
customer
LACSD
datetime