- Date
- 01/04/2018
- W/O
- 679249
- Weather
- Dry
- Operator/Surveyor
- R.VARGAS
- Sewer ID
- Z00520
- PipeID
- P05884
- Time
- 10:52 PM
- Certificate
- U-209-211
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5307
- Sewer Name
- 05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK
- City
- INGLEWOOD
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 10
- Purpose
- Routine Assessment
- Project
- WO_679249_TV05103_JAN2018
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 05 0659
- Downstream MH
- 05 0658
- Dir. of Survey
- Downstream
- Length Surveyed
- 353.7 ft.
- Total Length
- 353.7 ft.
- Structural Index
- 2
- Structural Quick
- 2600
- Structural Rating
- 12
- O&M Index
- 2
- O&M Quick
- 2212
- O&M Rating
- 6
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 18
Pipe schematic from manhole 05 0659 to 05 0658 Observation photos (4)

3.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

76.4 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

99.6 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

246.2 ft. - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES