Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 5, 2018, 10:57 AM
  • 05 0652_05 0651 _05012018_032314.mp4

Date
01/05/2018
W/O
679249
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00520
PipeID
P05877
Time
2:57 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5307
Sewer Name
05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK
City
INGLEWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
10
Purpose
Routine Assessment
Project
WO_679249_TV05103_JAN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
05 0652
Downstream MH
05 0651
Dir. of Survey
Downstream
Length Surveyed
330.8 ft.
Total Length
330.8 ft.
Structural Index
3
Structural Quick
4132
Structural Rating
10
O&M Index
2
O&M Quick
3121
O&M Rating
7
Overall Index
2
Overall Quick
Overall Rating
17
Pipe schematic from manhole 05 0652 to 05 0651
MH: 05 0652MH: 05 0651downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 06530 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK CAPPED0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK ACTIVE2.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start16.5 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES21.9 ft. FM - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES, Start63.6 ft. RFJ - Roots Fine Joint, from 08 to 09 o'clock, within 8 inches of joint: YES76.7 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 4"81.3 ft. RMJ - Roots Medium Joint, from 04 to 08 o'clock, 15 %, within 8 inches of joint: YESR, Start81.3 ft. FM - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES, Finish81.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start110.6 ft. RMJ - Roots Medium Joint, from 04 to 08 o'clock, 15 %, within 8 inches of joint: YESR, Finish124.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"124.9 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"195.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"246 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"297.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"326 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish330.8 ft. AMH - Downstream Manhole, Survey Ends - 05 0651330.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish330.8 ft. VC - Vermin Cockroach330.8 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK ACTIVE330.8 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK ACTIVE

Observation photos (6)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    16.5 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES, Start

    21.9 ft. - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 08 to 09 o'clock, within 8 inches of joint: YES

    63.6 ft. - Roots Fine Joint, from 08 to 09 o'clock, within 8 inches of joint: YES

  • Roots Medium Joint, from 04 to 08 o'clock, 15 %, within 8 inches of joint: YESR, Start

    81.3 ft. - Roots Medium Joint, from 04 to 08 o'clock, 15 %, within 8 inches of joint: YESR, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    81.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (25)

DistanceCodeObservation
0AMH05 0653
0MGOCONNECTION AT MH 3 O'CLOCK CAPPED
297.8TFC
326CM
81.3RMJ
246TFC
21.9FM
110.6RMJ
124.2TFC
2.4DAGS
124.9TBA
330.8AMH05 0651
0MWM
63.6RFJ
330.8DAGS
81.3FM
330.8VC
76.7TB
0MWL
81.3CM
330.8MGOCONNECTION AT MH 3 O'CLOCK ACTIVE
330.8MGOCONNECTION AT MH 9 O'CLOCK ACTIVE
16.5FL
0MGOCONNECTION AT MH 9 O'CLOCK ACTIVE
195.7TFC

Properties (4)

additional_info
SC346901
custom_field_two
3
customer
LACSD
datetime