Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 4, 2018, 08:50 AM
  • 05 0674_05 0673_04012018_010744.mp4

Date
01/04/2018
W/O
679249
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00520
PipeID
P05901
Time
12:50 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5306
Sewer Name
05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK
City
INGLEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
10
Purpose
Routine Assessment
Project
WO_679249_TV05103_JAN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 0673
Downstream MH
05 0674
Dir. of Survey
Upstream
Length Surveyed
324.1 ft.
Total Length
324.1 ft.
Structural Index
3
Structural Quick
4831
Structural Rating
38
O&M Index
1
O&M Quick
1200
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
40
Pipe schematic from manhole 05 0673 to 05 0674
MH: 05 0673MH: 05 0674upstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK ACTIVE0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK ACTIVE0 ft. AMH - Upstream Manhole, Survey Ends - 05 06740 ft. VC - Vermin Cockroach34.6 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish56.5 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start62.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4"67.6 ft. FS - Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES82.8 ft. CC - Crack Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES114.3 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"163.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"213.1 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"227.3 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES265.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4"289.5 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish310.6 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start314.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4"324.1 ft. MWL - Water Level, 10 %of cross sectional area324.1 ft. VC - Vermin Cockroach324.1 ft. MWM - Water Mark, 10 %of cross sectional area324.1 ft. AMH - Downstream Manhole, Survey Begins - 05 0673

Observation photos (5)

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

    13.5 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    96.8 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES

    241.3 ft. - Crack Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES

    256.5 ft. - Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

    267.6 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

Observations (21)

DistanceCodeObservation
209.8TFA
9.8TF
96.8CL
241.3CC
267.6FM
324.1MGOCONNECTION AT MH 3 O'CLOCK ACTIVE
324.1MGOCONNECTION AT MH 9 O'CLOCK ACTIVE
0MWL
0VC
324.1AMH05 0674
0MWM
0AMH05 0673
289.5FM
58.7TF
256.5FS
13.5FM
34.6FM
324.1VC
160.5TFC
261.7TF
111TFC

Properties (4)

additional_info
SC346475
custom_field_two
4
customer
LACSD
datetime
2018-01-04T00:50:30-08:00