- Date
- 01/04/2018
- W/O
- 679249
- Weather
- Dry
- Operator/Surveyor
- R.VARGAS
- Sewer ID
- Z00520
- PipeID
- P05901
- Time
- 12:50 AM
- Certificate
- U-209-211
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5306
- Sewer Name
- 05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK
- City
- INGLEWOOD
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 10
- Purpose
- Routine Assessment
- Project
- WO_679249_TV05103_JAN2018
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 05 0673
- Downstream MH
- 05 0674
- Dir. of Survey
- Upstream
- Length Surveyed
- 324.1 ft.
- Total Length
- 324.1 ft.
- Structural Index
- 3
- Structural Quick
- 4831
- Structural Rating
- 38
- O&M Index
- 1
- O&M Quick
- 1200
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 40
Pipe schematic from manhole 05 0673 to 05 0674 Observation photos (5)

13.5 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

96.8 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

241.3 ft. - Crack Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES

256.5 ft. - Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES

267.6 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start