Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 12, 2018, 06:43 AM
  • 05 0645A_05 0645 _11012018_230715.mp4

Date
01/11/2018
W/O
679249
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00520
PipeID
P18907
Time
10:43 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5372
Sewer Name
05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK
City
INGLEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Routine Assessment
Project
WO_679249_TV05103_JAN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
05 0645A
Downstream MH
05 0645
Dir. of Survey
Downstream
Length Surveyed
386 ft.
Total Length
386 ft.
Structural Index
3
Structural Quick
3M21
Structural Rating
215
O&M Index
3
O&M Quick
413C
O&M Rating
74
Overall Index
3
Overall Quick
Overall Rating
289
Pipe schematic from manhole 05 0645A to 05 0645
MH: 05 0645AMH: 05 0645downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 0645A0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start5 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - UNKNOWN18.4 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: NO27.4 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start55 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"106.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"134.2 ft. RPZ - Repair Other, within 8 inches of joint: YES - ABANDONED MH202.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"254.5 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"272.4 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS305 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"355.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"384.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish384.7 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish384.7 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish386 ft. AMH - Downstream Manhole, Survey Ends - 05 0645

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: NO

    18.4 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: NO

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    27.4 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Repair Other, within 8 inches of joint: YES - ABANDONED MH

    134.2 ft. - Repair Other, within 8 inches of joint: YES - ABANDONED MH

Observations (20)

DistanceCodeObservation
106.5TFC
27.4CM
0MWM
384.7DAGS
305TFC
384.7CM
134.2RPZABANDONED MH
202.9TFC
2DAGS
55TFC
0AMH05 0645A
272.4DSZDEBRIS
386AMH05 0645
0MGOACTIVE CONNECTION AT MH 9 O'CLOCK
384.7DSZ
355.2TFC
254.5TF
0MWL
5TFUNKNOWN
18.4CL

Properties (4)

additional_info
SC346449
custom_field_two
2
customer
LACSD
datetime
2018-01-11T22:43:06-08:00