Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 12, 2018, 11:00 AM
  • 05 0642_05 0641 _12012018_035146.mp4

Date
01/12/2018
W/O
679249
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00520
PipeID
P05867
Time
3:00 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5372
Sewer Name
05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK
City
HAWTHORNE
Loc. details
Airport
Location Code
M
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Routine Assessment
Project
WO_679249_TV05103_JAN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
05 0642
Downstream MH
05 0641
Dir. of Survey
Downstream
Length Surveyed
256.8 ft.
Total Length
256.8 ft.
Structural Index
2
Structural Quick
3122
Structural Rating
7
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
11
Pipe schematic from manhole 05 0642 to 05 0641
MH: 05 0642MH: 05 0641downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 06420 ft. MWL - Water Level, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start69.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"121.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"134 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES171.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"175 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES185.6 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES221.8 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"253.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish256.8 ft. AMH - Downstream Manhole, Survey Ends - 05 0641

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    185.6 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (13)

DistanceCodeObservation
171.4TFC
0MWM
0AMH05 0642
185.6CM
121.9TFC
253.6DAGS
221.8TBA
134CL
256.8AMH05 0641
0MWL
69.7TFC
2DAGS
175CL

Properties (4)

additional_info
SC346449
custom_field_two
3
customer
LACSD
datetime
2018-01-12T03:00:25-08:00