- Date
- 01/12/2018
- W/O
- 679249
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00520
- PipeID
- P05867
- Time
- 3:00 AM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5372
- Sewer Name
- 05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK
- City
- HAWTHORNE
- Loc. details
- Airport
- Location Code
- M
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 13
- Purpose
- Routine Assessment
- Project
- WO_679249_TV05103_JAN2018
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 05 0642
- Downstream MH
- 05 0641
- Dir. of Survey
- Downstream
- Length Surveyed
- 256.8 ft.
- Total Length
- 256.8 ft.
- Structural Index
- 2
- Structural Quick
- 3122
- Structural Rating
- 7
- O&M Index
- 2
- O&M Quick
- 2200
- O&M Rating
- 4
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 11
Pipe schematic from manhole 05 0642 to 05 0641 Observation photos (2)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

185.6 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES