Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 22, 2018, 09:21 AM
  • 15 0775_15 0774_2222018_013459.mp4

Date
02/22/2018
W/O
0691282
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00593
PipeID
P12976
Time
1:21 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0749R
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
04
Purpose
Maintenance Related
Project
20180222MDM_ARCADIA_SIERRA_MADRE_TRUNK_SECTS_2_5
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
15 0774
Downstream MH
15 0775
Dir. of Survey
Upstream
Length Surveyed
384.8 ft.
Total Length
384.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
1
O&M Quick
2213
O&M Rating
7
Overall Index
1
Overall Quick
Overall Rating
7
Pipe schematic from manhole 15 0774 to 15 0775
MH: 15 0774MH: 15 0775upstream0 ft. AMH - Upstream Manhole, Survey Ends - 1:45AM0.4 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. OPEN35.9 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Capped39.9 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Capped84.9 ft. RFJ - Roots Fine Joint, from 10 to 02 o'clock, within 8 inches of joint: YESR - 4%110.1 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open115.7 ft. RFJ - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YESR - 1%115.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped192 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open-80% ROOTS198.7 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active200.7 ft. RFJ - Roots Fine Joint, from 08 to 10 o'clock, within 8 inches of joint: YESR - 2%236.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped239 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open-1OO% ROOTS285.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped289.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped384.8 ft. AMH - Downstream Manhole, Survey Begins - 1:25AM384.8 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active384.8 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active384.8 ft. MWM - Water Mark, 30 %of cross sectional area384.8 ft. MWL - Water Level, 10 %of cross sectional area

Observations (20)

DistanceCodeObservation
299.9RFJ4%
184.1RFJ2%
384.4MGOConn. @ Mh, 9 O' Clock. OPEN
0AMH1:25AM
274.7TBOpen
0MGOConn. @ Mh, 9 O' Clock. Active
384.8AMH1:45AM
95.4TFCCapped
99.3TFCCapped
186.1TBActive
269.1RFJ1%
0MGOConn. @ Mh, 3 O' Clock. Active
348.9TFCCapped
148TFCCapped
145.8TFDOpen-1OO% ROOTS
0MWM
192.8TFDOpen-80% ROOTS
0MWL
269.1TFCCapped
344.9TFCCapped

Properties (3)

additional_info
POST ROOT CCTV ONLY
customer
LACSD
datetime
2018-02-22T01:21:45-08:00