Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 17, 2018, 12:58 PM
  • 08 0358A_08 0358_2172018_055223.mp4

Date
02/17/2018
W/O
0690350
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00003
PipeID
P00410
Time
4:58 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0744
Sewer Name
08 DAVIDSON CITY TRUNK, SECTS 1,2,&3
City
Carson
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
12
Purpose
Capital Improvement Program Assesment
Project
20180217VMR_DAVIDSON_CITY_TRUNK_SECTS_123
Material
NRCP
Shape
Circular
Height
18 in.
Upstream MH
08 0358A
Downstream MH
08 0358
Dir. of Survey
Downstream
Length Surveyed
131.8 ft.
Total Length
131.8 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole 08 0358A to 08 0358
MH: 08 0358AMH: 08 0358downstream0 ft. AMH - Upstream Manhole, Survey Begins - 06:00 AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area1.4 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES3 ft. SAVC - Surface Aggregate Visible Chemical, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - 40% Scattered Mag Coat46 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO - Rags55.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4" - Open87.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"112.5 ft. TFD - Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: YES, 1", 1" - Capped127.8 ft. SAVC - Surface Aggregate Visible Chemical, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - 40% Scattered Mag Coat131.8 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: YES, 4"131.8 ft. AMH - Downstream Manhole, Survey Ends - 06:15 AM

Observation photos (2)

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES

    1.4 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: YES, 1", 1" - Capped

    112.5 ft. - Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: YES, 1", 1" - Capped

Observations (12)

DistanceCodeObservation
55.2TFOpen
3SAVC40% Scattered Mag Coat
127.8SAVC40% Scattered Mag Coat
1.4SAV
112.5TFDCapped
131.8TFC
0AMH06:00 AM
87.9TFC
0MWL
46DSZRags
0MWM
131.8AMH06:15 AM

Properties (3)

custom_field_two
3
customer
LACSD
datetime
2018-02-17T04:58:06-08:00