Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 17, 2018, 08:48 AM
  • 08 0361_08 0360_2172018_051024.mp4

Date
02/17/2018
W/O
0690350
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00003
PipeID
P00413
Time
12:48 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0744
Sewer Name
08 DAVIDSON CITY TRUNK, SECTS 1,2,&3
City
Carson
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
12
Purpose
Capital Improvement Program Assesment
Project
20180217VMR_DAVIDSON_CITY_TRUNK_SECTS_123
Material
NRCP
Shape
Circular
Height
18 in.
Upstream MH
08 0361
Downstream MH
08 0360
Dir. of Survey
Downstream
Length Surveyed
142.9 ft.
Total Length
142.9 ft.
Structural Index
2
Structural Quick
3122
Structural Rating
7
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
7
Pipe schematic from manhole 08 0361 to 08 0360
MH: 08 0361MH: 08 0360downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 8"0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05:10 AM1.1 ft. SAVC - Surface Aggregate Visible Chemical, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - Mag Coat36.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4"54.8 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES84.5 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4" - Open102.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"120.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"138.9 ft. SAVC - Surface Aggregate Visible Chemical, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish138.9 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES141.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"142.9 ft. AMH - Downstream Manhole, Survey Begins - 05:25 Am

Observations (14)

DistanceCodeObservation
0MWL
54.8CL
1.1SAVCMag Coat
0TFA
138.9SAVC
138.9CL
36.6TF
0MWM
0AMH05:10 AM
141.9TFC
120.6TFC
84.5TFOpen
102.7TFC
142.9AMH05:25 Am

Properties (3)

custom_field_two
3
customer
LACSD
datetime
2018-02-17T00:48:46-08:00