Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 17, 2018, 08:47 AM
  • 08 0362_08 0361_2172018_040538.mp4

Date
02/17/2018
W/O
0690350
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00003
PipeID
P00414
Time
12:47 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0743
Sewer Name
08 DAVIDSON CITY TRUNK, SECTS 1,2,&3
City
Carson
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
12
Purpose
Capital Improvement Program Assesment
Project
20180217VMR_DAVIDSON_CITY_TRUNK_SECTS_123
Material
NRCP
Shape
Circular
Height
18 in.
Upstream MH
08 0362
Downstream MH
08 0361
Dir. of Survey
Downstream
Length Surveyed
142.5 ft.
Total Length
142.5 ft.
Structural Index
2
Structural Quick
3321
Structural Rating
13
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
13
Pipe schematic from manhole 08 0362 to 08 0361
MH: 08 0362MH: 08 0361downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 04:10 AM0 ft. MWL - Water Level, 15 %of cross sectional area4.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES - Moderate to Severe4.3 ft. CM - Crack Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES4.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"6 ft. SAVC - Surface Aggregate Visible Chemical, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - Mag Coat34.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"34.5 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES64.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"92 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4"106.1 ft. CC - Crack Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES115.1 ft. CC - Crack Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES139.1 ft. SAVC - Surface Aggregate Visible Chemical, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - Mag Coat142.1 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 4"142.5 ft. AMH - Downstream Manhole, Survey Ends - 04:25 AM

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES - Moderate to Severe

    4.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES - Moderate to Severe

Observations (16)

DistanceCodeObservation
106.1CC
115.1CC
142.1TFA
6SAVCMag Coat
0MWM
0AMH04:10 AM
92TF
4.6TFC
4.3CM
34.5TFC
0MWL
34.5CL
139.1SAVCMag Coat
64.5TFC
142.5AMH04:25 AM
4.2SAVModerate to Severe

Properties (3)

custom_field_two
3
customer
LACSD
datetime
2018-02-17T00:47:42-08:00