Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 16, 2018, 08:51 AM
  • 01 0429_01 0428_2162018_010200.mp4

Date
02/16/2018
W/O
0689084
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00208
PipeID
P00910
Time
12:51 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0738
Sewer Name
01 HOLMES-WILLOWBROOK TRUNK
City
WILLBROOK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Capital Improvement Program Assesment
Project
20180216MDM_HOLMES_WILLOWBROOK_TRUNK
Material
NRCP
Shape
Circular
Height
18 in.
Upstream MH
01 0428
Downstream MH
01 0429
Dir. of Survey
Upstream
Length Surveyed
157.8 ft.
Total Length
157.8 ft.
Structural Index
3
Structural Quick
4121
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 01 0428 to 01 0429
MH: 01 0428MH: 01 0429upstream0 ft. AMH - Upstream Manhole, Survey Ends - 1:20AM0.6 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active0.6 ft. MGO - General Observation - MAG COAT 90% FINISH0.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - PEELING CONCRETE SEVERE AGG ATTCHED0.6 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG5.1 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Capped26.1 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Capped31.8 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Active39.1 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Capped53.6 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Capped74.3 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6", 6" - Capped79.5 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Open92.7 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Capped97.9 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Capped107.9 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Capped120.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped155.8 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG155.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTCHED155.8 ft. MGO - General Observation - MAG COAT 90% START 8:00 TO 4:00157.8 ft. MWL - Water Level, 10 %of cross sectional area157.8 ft. AMH - Downstream Manhole, Survey Begins - 12:55AM157.8 ft. MWM - Water Mark, 30 %of cross sectional area157.8 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active

Observation photos (3)

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTCHED

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTCHED

  • General Observation - MAG COAT 90% START 8:00 TO 4:00

    2 ft. - General Observation - MAG COAT 90% START 8:00 TO 4:00

Observations (23)

DistanceCodeObservation
49.9TFCCapped
126TFActive
118.7TFCCapped
2SAMSEVERE AGG
59.9TFCCapped
65.1TFCCapped
131.7TFCCapped
157.2MGOConn. @ Mh, 9 O' Clock. Active
0MWL
157.8AMH1:20AM
83.5TFCCapped
37TFCCapped
157.2MGOMAG COAT 90% FINISH
0AMH12:55AM
157.2SSSPEELING CONCRETE SEVERE AGG ATTCHED
157.2SAMSEVERE AGG
2SSSPEELING CONCRETE SEVERE AGG ATTCHED
104.2TFCCapped
78.3TFOpen
0MWM
2MGOMAG COAT 90% START 8:00 TO 4:00
152.7TFCCapped
0MGOConn. @ Mh, 3 O' Clock. Active

Properties (4)

custom_field_three
PEELING CONCRETE SEVERE AGG ATTCHED
custom_field_two
2
customer
LACSD
datetime
2018-02-16T00:51:06-08:00