Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 30, 2018, 10:50 AM
  • 15 0763_15 0762 _30012018_030718.mp4

Date
01/30/2018
W/O
684713
Weather
Dry
Operator/Surveyor
K. ADAME
Sewer ID
Z00593
PipeID
P12964
Time
2:50 AM
Certificate
U-0817-07009000
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4858
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
08
Purpose
Routine Assessment
Project
WO_684713_TV15146_FEB2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
15 0763
Downstream MH
15 0762
Dir. of Survey
Downstream
Length Surveyed
322.8 ft.
Total Length
322.8 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 15 0763 to 15 0762
MH: 15 0763MH: 15 0762downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 07632.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start103.5 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6"106.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"166.9 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6"166.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"170.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"208 ft. RFJ - Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YES239.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"242.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"244.5 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: YES, 6"245.9 ft. TB - Tap Break-In, at 09 o'clock, -, within 8 inches of joint: YES, 6"283.9 ft. TB - Tap Break-In, at 09 o'clock, -, within 8 inches of joint: YES, 6"291.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"320.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish322.8 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK322.8 ft. AMH - Downstream Manhole, Survey Ends - 15 0762

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    2.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YES

    208 ft. - Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YES

Observations (21)

DistanceCodeObservation
0MWL
291.4TF
170.2TFC
322.8MGOCONNECTION AT MH 3 O'CLOCK
322.8AMH15 0762
283.9TB
208RFJ
239.9TFC
0MGOCONNECTION AT MH 9 O'CLOCK
244.5TB
106.4TF
2.6SAV
0MGOCONNECTION AT MH 3 O'CLOCK
166.9TB
320.7SAV
245.9TB
103.5TF
0MWM
166.9TF
242.8TFC
0AMH15 0763

Properties (4)

additional_info
SC346882
custom_field_two
4
customer
LACSD
datetime
2018-01-30T02:50:48-08:00