Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 30, 2018, 10:31 AM
  • 15 0764_15 0763 _30012018_024918.mp4

Date
01/30/2018
W/O
684713
Weather
Dry
Operator/Surveyor
K. ADAME
Sewer ID
Z00593
PipeID
P12965
Time
2:31 AM
Certificate
U-0817-07009000
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4858
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
08
Purpose
Routine Assessment
Project
WO_684713_TV15146_FEB2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
15 0764
Downstream MH
15 0763
Dir. of Survey
Downstream
Length Surveyed
352 ft.
Total Length
352 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 15 0764 to 15 0763
MH: 15 0764MH: 15 0763downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 07640 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK5.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start81.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"84.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"124.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"127.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"166.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"169.2 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6"169.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"199.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"222.1 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES - ROCK266 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"269.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"349.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish352 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK352 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK352 ft. AMH - Downstream Manhole, Survey Ends - 15 0763

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    5.4 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Deposits Settled Other,  15 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES - ROCK

    222.1 ft. - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES - ROCK

Observations (20)

DistanceCodeObservation
84.5TF
349.8SAV
199.6TFC
352MGOCONNECTION AT MH 3 O'CLOCK
124.1TF
166.2TFC
266TF
81.1TF
127.1TF
5.4SAV
0MWM
222.1DSZROCK
352MGOCONNECTION AT MH 9 O'CLOCK
0MWL
269.5TFC
169.2TB
169.2TF
0AMH15 0764
352AMH15 0763
0MGOCONNECTION AT MH 9 O'CLOCK

Properties (4)

additional_info
SC346882
custom_field_two
4
customer
LACSD
datetime
2018-01-30T02:31:20-08:00