Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 30, 2016, 08:17 AM
  • 18 0525 SW_18 0524 _30062016_011723.mp4

Date
06/30/2016
W/O
579947
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00705
PipeID
P20176
Time
1:17 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3550
Sewer Name
18 SOUTH PLANT OUTFALL TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
10
Purpose
Routine Assessment
Project
WO_579947_TV18055_JULY2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0524
Downstream MH
18 0525 SW
Dir. of Survey
Upstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 18 0524 to 18 0525 SW
MH: 18 0524MH: 18 0525 SWupstream0 ft. MSA - Survey Abandoned - VIEW OF UPLEG OF SW SIPHON.0 ft. DAGS - Deposits Attached Grease, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES2 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. AMH - Downstream Manhole, Survey Begins - 18 05242 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (2)

  • Survey Abandoned - VIEW OF UPLEG OF SW SIPHON.

    2 ft. - Survey Abandoned - VIEW OF UPLEG OF SW SIPHON.

  • Deposits Attached Grease, 15 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES

    2 ft. - Deposits Attached Grease, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES

Observations (5)

DistanceCodeObservation
2MSAVIEW OF UPLEG OF SW SIPHON.
0MWM
0AMH18 0524
2DAGS
0MWL

Properties (5)

additional_info
SC305779
custom_field_two
4
customer
LACSD
datetime
2016-06-30T01:17:05-07:00
sewer_category
Siphon