Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 3, 2016, 08:49 AM
  • 18 0431_18 0430_20160503_020710.mp4

Date
05/03/2016
W/O
569081
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00675
PipeID
P14279
Time
1:49 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3360
Sewer Name
18 FLORENCE AVENUE TRUNK
City
SANTA FE SPRINGS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_569081_TV18097_MAY2016
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Upstream MH
18 0431
Downstream MH
18 0430
Dir. of Survey
Downstream
Length Surveyed
442.8 ft.
Total Length
442.8 ft.
Structural Index
5
Structural Quick
5100
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
5
Overall Quick
Overall Rating
5
Pipe schematic from manhole 18 0431 to 18 0430
MH: 18 0431MH: 18 0430downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 04310 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK0 ft. MWM - Water Mark, 5 %of cross sectional area2.1 ft. MGO - General Observation - MAG COAT 85%21.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"73.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"122 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"173.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"221.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"273.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"321.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"373 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"412.2 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO, Start422.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"438.3 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO, Finish442.8 ft. AMH - Downstream Manhole, Survey Ends - 18 0430

Observation photos (1)

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO, Start

    412.2 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO, Start

Observations (17)

DistanceCodeObservation
73.1TF
173.2TFC
2.1MGOMAG COAT 85%
273.1TFC
438.3SRV
412.2SRV
0AMH18 0431
0MWL
442.8AMH18 0430
422.1TFC
0MGOLATERAL AT MH 3 OCLOCK
373TFC
21.2TFC
122TFC
221.2TFC
321.6TFC
0MWM

Properties (5)

additional_info
SC300357
custom_field_two
3
customer
LACSD
datetime
2016-05-03T01:49:36-07:00
sewer_category
GRAVITY