Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 3, 2016, 07:43 AM
  • 18 0451_18 0450_20160504_010756.mp4

Date
05/03/2016
W/O
569081
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00675
PipeID
P14302
Time
12:43 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3361
Sewer Name
18 FLORENCE AVENUE TRUNK
City
SANTA FE SPRINGS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_569081_TV18097_MAY2016
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
18 0451
Downstream MH
18 0450
Dir. of Survey
Downstream
Length Surveyed
317.6 ft.
Total Length
317.6 ft.
Structural Index
3
Structural Quick
3311
Structural Rating
10
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
14
Pipe schematic from manhole 18 0451 to 18 0450
MH: 18 0451MH: 18 0450downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 04510 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - LATERAL AT MH 6 OCLOCK0 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK10.8 ft. CC - Crack Circumferential, from 06 to 11 o'clock, within 8 inches of joint: YES21.4 ft. CM - Crack Multiple, from 07 to 02 o'clock, within 8 inches of joint: YES22.8 ft. CM - Crack Multiple, from 07 to 11 o'clock, within 8 inches of joint: NO31.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start31.7 ft. DSF - Deposits Settled Fine, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start53.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6", 6"68.5 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start80.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"106.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"127 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"152.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"178.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"204.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"230.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"256.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"261.8 ft. DSF - Deposits Settled Fine, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Finish282 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"302.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"316 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Finish316 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish317.6 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK CAPPED317.6 ft. AMH - Downstream Manhole, Survey Ends - 18 0450

Observation photos (6)

  • Crack Circumferential, from 06 to 11 o'clock, within 8 inches of joint: YES

    10.8 ft. - Crack Circumferential, from 06 to 11 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 02 o'clock, within 8 inches of joint: YES

    21.4 ft. - Crack Multiple, from 07 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 11 o'clock, within 8 inches of joint: NO

    22.8 ft. - Crack Multiple, from 07 to 11 o'clock, within 8 inches of joint: NO

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    31.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Settled Fine,  10 %of cross sectional area, at 06 o'clock,  , within 8 inches of joint: YES, Start

    31.7 ft. - Deposits Settled Fine, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 05 o'clock,  , within 8 inches of joint: YES, Start

    68.5 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start

Observations (27)

DistanceCodeObservation
316DAE
152.8TFC
256.4TFC
0MWM
22.8CM
178.9TFC
68.5DAE
31.7CM
230.5TFC
127TFC
10.8CC
0AMH18 0451
106.2TFC
316CM
317.6MGOLATERAL AT MH 3 OCLOCK CAPPED
31.7DSF
282TFC
204.7TFC
0MWL
0MGOLATERAL AT MH 6 OCLOCK
317.6AMH18 0450
261.8DSF
21.4CM
53.9TFC
302.3TFC
80.2TFC
0MGOLATERAL AT MH 3 OCLOCK

Properties (5)

additional_info
SC300358
custom_field_two
3
customer
LACSD
datetime
2016-05-03T00:43:19-07:00
sewer_category
GRAVITY