- Date
- 09/01/2015
- W/O
- 521021
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00696
- PipeID
- P14518
- Time
- 11:49 PM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K2671
- Sewer Name
- 18 PHOEBE AVENUE TRUNK
- City
- LA MIRADA
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 36
- Purpose
- Routine Assessment
- Project
- RFIR_WO_521021_TV18081_AUG2015
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Upstream MH
- 18 0669
- Downstream MH
- 18 0668
- Dir. of Survey
- Downstream
- Length Surveyed
- 350.5 ft.
- Total Length
- 350.5 ft.
- Structural Index
- 3
- Structural Quick
- 4133
- Structural Rating
- 15
- O&M Index
- 2
- O&M Quick
- 2400
- O&M Rating
- 8
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 23
Pipe schematic from manhole 18 0669 to 18 0668 Observation photos (6)

12.7 ft. - Obstacles Rocks, 10 %of cross sectional area, from 05 to 07 o'clock

26.2 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

42.1 ft. - Obstacles Rocks, 10 %of cross sectional area, from 05 to 07 o'clock

145.1 ft. - Crack Spiral, from 08 to 10 o'clock, within 8 inches of joint: YES

188.6 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

221.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start