Section#13_J 0502_J 0197__2122018__G6958.mp4
0 ft. - General Observation - MH CONN 9:00 STOPLOG IN PLACE
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
2 ft. - General Observation - MAG COAT 5% START 8:00 TO 4:00
12.4 ft. - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - SEVERE AGG
64.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETEW
64.4 ft. - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC
117.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG VERY SPORATIC
249.2 ft. - Surface Aggregate Visible, from 08 to 12 o'clock, within 8 inches of joint: NO - SEVERE AGG
254.6 ft. - General Observation - MAG COAT 30% START
285.6 ft. - General Observation - MAG COAT 5% START
| Distance | Code | Observation |
|---|---|---|
| 12.4 | SAV | SEVERE AGG |
| 320.1 | SAV | SEVERE AGG SPORATIC |
| 249.2 | SAV | SEVERE AGG |
| 320.7 | AMH | 5:25AM |
| 0 | MGO | MH CONN 9:00 STOPLOG IN PLACE |
| 320.1 | SSS | BLISTERING PEELING CONCRETE |
| 64.4 | SSS | PEELING CONCRETEW |
| 64.4 | SAV | SEVERE AGG SPORATIC |
| 0 | MWM | — |
| 0 | AMH | 4:40AM |
| 2 | SSS | BLISTERING PEELING CONCRETE |
| 254.6 | MGO | MAG COAT 30% START |
| 0 | MWL | — |
| 2 | MGO | MAG COAT 5% START 8:00 TO 4:00 |
| 285.6 | MGO | MAG COAT 5% START |
| 117.2 | SAV | SEVERE AGG VERY SPORATIC |
| 320.1 | MGO | MAG COAT 5% FINISH |