Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 26, 2018, 10:19 AM
  • 29 0192_29 0191 _26012018_023631.mp4

Date
01/26/2018
W/O
1590881
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01025
PipeID
P24089
Time
2:19 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5424
Sewer Name
29 28TH STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
02
Purpose
Routine Assessment
Project
WO_684841_TV29101_FEB2018
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0191
Downstream MH
29 0192
Dir. of Survey
Upstream
Length Surveyed
254.9 ft.
Total Length
255 ft.
Structural Index
4
Structural Quick
4G3A
Structural Rating
192
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
192
Pipe schematic from manhole 29 0191 to 29 0192
MH: 29 0191MH: 29 0192upstream0 ft. AMH - Upstream Manhole, Survey Ends - 29 01922.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish51.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"53.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"57.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"101.8 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"108.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"134.5 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"153.8 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"157 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"192.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish192.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start195.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES205.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"208.9 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"242.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"245.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"250.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start255 ft. MWM - Water Mark, 5 %of cross sectional area255 ft. MWL - Water Level, 5 %of cross sectional area255 ft. AMH - Downstream Manhole, Survey Begins - 29 0191

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    59.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    62.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (21)

DistanceCodeObservation
120.5TF
62.1CM
98TFC
153.2TFC
12.3TF
62.1FM
9.5TF
46.1TFC
0MWM
252.7FM
101.2TFC
201.1TFC
4.3CM
255AMH29 0192
203.3TB
0MWL
59.1FM
49.5TF
197.8TFC
146.7TFC
0AMH29 0191

Properties (5)

additional_info
SC347059
custom_field_two
2
customer
LACSD
datetime
2018-01-26T02:19:53-08:00
sewer_category
Gravity