- Date
- 09/28/2017
- W/O
- 663060
- Weather
- Dry
- Operator/Surveyor
- R.VARGAS
- Sewer ID
- Z00659
- PipeID
- P13600
- Time
- 10:55 PM
- Certificate
- U-209-211
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4281
- Sewer Name
- 16 LAMANDA PARK TRUNK
- City
- PASADENA
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 15
- Purpose
- Routine Assessment
- Project
- WO_663060_TV16078_OCT2017
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 24 in.
- Width
- 24 in.
- Upstream MH
- 16 0549
- Downstream MH
- 16 0548
- Dir. of Survey
- Downstream
- Length Surveyed
- 230.3 ft.
- Total Length
- 230.3 ft.
- Structural Index
- 3
- Structural Quick
- 3H00
- Structural Rating
- 135
- O&M Index
- 2
- O&M Quick
- 2H11
- O&M Rating
- 93
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 228
Pipe schematic from manhole 16 0549 to 16 0548 Observation photos (2)

2.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

2.9 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start