Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 10, 2018, 08:14 AM
  • 22 0263_22 0262 _10012018_001526.mp4

Date
01/10/2018
W/O
679393
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00793
PipeID
P16545
Time
12:14 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5409
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
36
Purpose
Routine Assessment
Project
WO_679393_TV22016_JAN2018
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0263
Downstream MH
22 0262
Dir. of Survey
Downstream
Length Surveyed
253.7 ft.
Total Length
253.7 ft.
Structural Index
3
Structural Quick
3I00
Structural Rating
150
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
3
Overall Quick
Overall Rating
151
Pipe schematic from manhole 22 0263 to 22 0262
MH: 22 0263MH: 22 0262downstream0 ft. AMH - Upstream Manhole, Survey Begins - 22 02630 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area2.7 ft. MGO - General Observation - MAG COAT2.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start12.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"55.1 ft. RFL - Roots Fine Lateral, at 10 o'clock55.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"64.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"112.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"158.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"161.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"210.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"253.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish253.7 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK253.7 ft. AMH - Downstream Manhole, Survey Ends - 22 0262

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.7 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (16)

DistanceCodeObservation
55.1RFL
253.7SAP
112.9TFC
2.7MGOMAG COAT
64.8TFC
0AMH22 0263
55.1TF
253.7MGOCONNECTION AT MH 9 O'CLOCK
158.6TFC
2.7SAP
0MWM
161.6TFC
12.9TFC
0MWL
210.2TFC
253.7AMH22 0262

Properties (5)

additional_info
SC346783
custom_field_two
3
customer
LACSD
datetime
2018-01-10T00:14:59-08:00
sewer_category
Gravity