- Date
- 01/10/2018
- W/O
- 679393
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00793
- PipeID
- P16535
- Time
- 2:34 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5409
- Sewer Name
- 22 CAMERON TRUNK, SECTS 1,2,&3
- City
- WEST COVINA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 36
- Purpose
- Routine Assessment
- Project
- WO_679393_TV22016_JAN2018
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 22 0253
- Downstream MH
- 22 0252
- Dir. of Survey
- Downstream
- Length Surveyed
- 363.6 ft.
- Total Length
- 363.6 ft.
- Structural Index
- 2
- Structural Quick
- 322I
- Structural Rating
- 110
- O&M Index
- 1
- O&M Quick
- 1100
- O&M Rating
- 1
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 111
Pipe schematic from manhole 22 0253 to 22 0252 Observation photos (2)

2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

7.7 ft. - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES