- Date
- 01/08/2018
- W/O
- 679260
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00793
- PipeID
- P16578
- Time
- 3:32 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5406
- Sewer Name
- 22 CAMERON TRUNK, SECTS 1,2,&3
- City
- WEST COVINA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 32
- Purpose
- Routine Assessment
- Project
- WO_679260_TV22014_JAN2018
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 22 0291
- Downstream MH
- 22 0292
- Dir. of Survey
- Upstream
- Length Surveyed
- 428.7 ft.
- Total Length
- 428.7 ft.
- Structural Index
- 3
- Structural Quick
- 3P2P
- Structural Rating
- 425
- O&M Index
- 4
- O&M Quick
- 4131
- O&M Rating
- 7
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 432
Pipe schematic from manhole 22 0291 to 22 0292 Observation photos (3)

2.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

107 ft. - Roots Medium Lateral, at 10 o'clock, 40 %, within 8 inches of joint: NO