Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 8, 2018, 09:45 AM
  • 22 0297_22 0296_08012018_014549.mp4

Date
01/08/2018
W/O
679260
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00793
PipeID
P16583
Time
1:45 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5406
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
32
Purpose
Routine Assessment
Project
WO_679260_TV22014_JAN2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
22 0296
Downstream MH
22 0297
Dir. of Survey
Upstream
Length Surveyed
421.2 ft.
Total Length
421.2 ft.
Structural Index
3
Structural Quick
3P2O
Structural Rating
413
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
413
Pipe schematic from manhole 22 0296 to 22 0297
MH: 22 0296MH: 22 0297upstream0 ft. AMH - Upstream Manhole, Survey Ends - 22 02972 ft. SSS - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish25.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"62.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"88.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"127.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"156.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"186.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"213 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"251.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"284 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"303.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"354 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"358.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"413.2 ft. SSS - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start415.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"419.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start421.2 ft. MWM - Water Mark, 15 %of cross sectional area421.2 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK421.2 ft. AMH - Downstream Manhole, Survey Begins - 22 0296421.2 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    8 ft. - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

Observations (22)

DistanceCodeObservation
170TF
2.1SAP
67.2TF
419.2SSS
117.8TF
419.2SAP
137.2TF
421.2AMH22 0297
358.3TF
264.5TF
63.1TFC
0MWM
6TF
0MGOCONNECTION AT MH 9 O'CLOCK
0AMH22 0296
293.8TF
0MWL
208.2TFC
234.5TF
395.3TFC
8SSS
332.9TFC

Properties (4)

additional_info
SC346780
custom_field_two
2
customer
LACSD
datetime
2018-01-08T01:45:42-08:00