- Date
- 02/01/2018
- W/O
- 0686794
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00228
- PipeID
- P01803
- Time
- 1:33 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G6941
- Sewer Name
- 01 WRIGHT ROAD TRUNK
- City
- BELL
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 08
- Purpose
- Capital Improvement Program Assesment
- Project
- 20180127MDM_WRIGHT_ROAD_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 24 in.
- Upstream MH
- 01 0966
- Downstream MH
- 01 0965
- Dir. of Survey
- Downstream
- Length Surveyed
- 193.6 ft.
- Total Length
- 193.6 ft.
- Structural Index
- 3
- Structural Quick
- 3D22
- Structural Rating
- 85
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 85
Pipe schematic from manhole 01 0966 to 01 0965 Observation photos (5)

4 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT

13.8 ft. - General Observation - 24" VCP

133.9 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT

146.3 ft. - General Observation - SLIGHT LONG FRACTURE 12:00

149.3 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: NO - SLIGHT